Implantatiechniek en uitkomsten van bioresorbeerbare scaffolds: ABSORB-analyses
Gepoolde analyse van ABSORB-trials naar het effect van implantatiechniek op BRS-uitkomsten. Correct sizing en hoge-druk nadilatatie waren cruciaal.
Abstract (original)
BACKGROUND: Procedural technique may affect clinical outcomes after bioresorbable vascular scaffold (BVS) implantation. Prior studies suggesting such a relationship have not adjusted for baseline patient and lesion characteristics that may have influenced operator choice of technique and outcomes. OBJECTIVES: This study sought to determine whether target lesion failure (TLF) (cardiac death, target-vessel myocardial infarction, or ischemia-driven target lesion revascularization) and scaffold thrombosis (ScT) rates within 3 years of BVS implantation are affected by operator technique (vessel size selection and pre- and post-dilation parameters). METHODS: TLF and ScT rates were determined in 2,973 patients with 3,149 BVS-treated coronary artery lesions from 5 prospective studies (ABSORB II, ABSORB China, ABSORB Japan, ABSORB III, and ABSORB Extend). Outcomes through 3 years (and between 0 to 1 and 1 to 3 years) were assessed according to pre-specified definitions of optimal technique (pre-dilation, vessel sizing, and post-dilation). Multivariable analysis was used to adjust for differences in up to 18 patient and lesion characteristics. RESULTS: Optimal pre-dilation (balloon to core laboratory-derived reference vessel diameter ratio ≥1:1), vessel size selection (reference vessel diameter ≥2.25 mm and ≤3.75 mm), and post-dilation (with a noncompliant balloon at ≥18 atm and larger than the nominal scaffold diameter, but not by >0.5 mm larger) in all BVS-treated lesions were performed in 59.2%, 81.6%, and 12.4% of patients, respectively. BVS implantation in properly sized vessels was an independent predictor of freedom from TLF through 1 year (hazard ratio [HR]: 0.67; p = 0.01) and through 3 years (HR: 0.72; p = 0.01), and of freedom from ScT through 1 year (HR: 0.36; p = 0.004). Aggressive pre-dilation was an independent predictor of freedom from ScT between 1 and 3 years (HR: 0.44; p = 0.03), and optimal post-dilation was an independent predictor of freedom from TLF between 1 and 3 years (HR: 0.55; p = 0.05). CONCLUSIONS: In the present large-scale analysis from the major ABSORB studies, after multivariable adjustment for baseline patient and lesion characteristics, vessel sizing and operator technique were strongly associated with BVS-related outcomes during 3-year follow-up. (ABSORB II Randomized Controlled Trial [ABSORB II]; NCT01425281; ABSORB III Randomized Controlled Trial [RCT] [ABSORB-III]; NCT01751906; A Clinical Evaluation of Absorb Bioresorbable Vascular Scaffold [Absorb BVS] System in Chinese Population-ABSORB CHINA Randomized Controlled Trial [RCT] [ABSORB CHINA]; NCT01923740; ABSORB EXTEND Clinical Investigation [ABSORB EXTEND]; NCT01023789; AVJ-301 Clinical Trial: A Clinical Evaluation of AVJ-301 [Absorb BVS] in Japanese Population [ABSORB JAPAN]; NCT01844284).
Dit artikel is een samenvatting van een publicatie in Journal of the American College of Cardiology. Voor het volledige artikel, alle details en referenties verwijzen wij u naar de oorspronkelijke bron.
Lees het volledige artikelDOI: 10.1016/j.jacc.2017.09.1106