Variatie in Lp(a)-metingen kan patiënten verkeerd inschatten — methodenvergelijking

Een studie onderzocht de analytische prestaties van zes geautomatiseerde Lp(a)-assays en de consequenties voor cardiovasculaire risicotresholds. Hoewel de methoden goed correleerden, leidde de variatie tot een misclassificatierisico van tot 17,2% bij gebruik van de EAS of ACC/AHA-cutoffs. Dit benadrukt de noodzaak van standaardisatie en het gebruik van nmol/L om foutieve risicobeoordelingen in de klinische praktijk te voorkomen.

Abstract (original)

OBJECTIVES: The study was designed to evaluate the analytical performances of six automated immunoturbidimetric lipoprotein(a) (Lp(a)) assays, each corresponding to a combination of a reagent and an analyzer (Binding Site Optilite Lp(a) kit, Diagam Lp(a) reagent on Mindray BS480, Diagam Lp(a) reagent on Roche c502, Randox Lp(a) reagent on IDS-ISYS, Roche Tinaquant LPA2 on Roche c702 and Siemens Atellica CH Lp(a)/Atellica® CH 930) using results expressed in mg/dL or nmol/L. METHODS: Imprecision was assessed on manufacturer controls according to the CLSI EP15-A3 protocol. One hundred and 45 patient serum samples from the cardiology department were assessed to compare each method using Spearman's correlation, Passing-Bablok regression and Bland-Altman analyses. Percent agreement was calculated according to the European Atherosclerosis Society and American College of Cardiology/American Heart Association Lp(a) cut-offs for cardiovascular risk. RESULTS: All immunoturbidimetric methods achieved the desirable imprecision of 5.1 % based on biological variation. Highly significant correlations were found across multiple comparisons (p<0.001). The absolute mean of the difference according to Bland-Altman ranged between 0.4 and 2.6 for Lp(a) assays in mg/dL and between 0.6 and 6.5 for Lp(a) assays in nmol/L. The percent agreement between two assays varied from 87.6 to 96.6 % and from 82.8 to 93.8 % using the EAS or the ACC/AHA thresholds. CONCLUSIONS: Despite acceptable correlation among the six Lp(a) turbidimetric assays, a risk of "misclassifications" between two assays up to 12.4 % with the EAS recommendations and 17.2 % with the ACC/AHA guideline remains a major concern. Standardization of methods, including expression of results in nmol/L is needed.

Dit artikel is een samenvatting van een publicatie in Clinical chemistry and laboratory medicine. Voor het volledige artikel, alle details en referenties verwijzen wij u naar de oorspronkelijke bron.

Lees het volledige artikel

DOI: 10.1515/cclm-2026-1481

Wilt u op de hoogte blijven?

Gratis: de maandelijkse nieuwsbrief met het nieuwsoverzicht, en de site afgestemd op uw vakgebied.

Schrijf u nu in