Volledig linkszijdig reverse remodelling bij CRT: MADIT-CRT-substudie
MADIT-CRT-substudie naar de klinische implicaties van volledig linkszijdig reverse remodelling bij patiënten met CRT. Super-responders met normalisatie van LV-functie hebben een uitstekende prognose.
Abstract (original)
BACKGROUND: Clinical implications of complete left-sided reverse remodeling due to cardiac resynchronization therapy with a defibrillator (CRT-D), defined as reduction in both left ventricular end-systolic volume (LVESV) and left atrial volume (LAV), are unknown. OBJECTIVES: This study aimed to evaluate the rate and predictive value of complete left-sided reverse remodeling on heart failure (HF) and death events in CRT-D patients with left bundle branch block (LBBB) enrolled in MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy). METHODS: The study population comprised 533 CRT-D patients with LBBB, 212 (40%) with complete left-sided reverse remodeling (above-median change in both LAV and LVESV), 115 (22%) with discordant reverse remodeling (above-median change in only LAV or LVESV), and 206 (38%) with lesser reverse remodeling (below-median LAV and LVESV change). The primary endpoint was HF or death; secondary endpoints included HF alone and death alone during long-term follow-up. RESULTS: Patients with complete left-sided reverse remodeling had a significantly lower rate of HF or death than those with discordant reverse remodeling or lesser reverse remodeling (p < 0.001). Multivariate Cox proportional hazard models consistently showed a decreased risk for HF and death in patients with complete reverse remodeling compared with discordant reverse remodeling or lesser reverse remodeling (hazard ratio: 0.66 per each group; 95% CI: 0.50 to 0.85; p = 0.002). This finding was similar for HF alone and death alone. CONCLUSIONS: In MADIT-CRT, >20% of CRT-D patients exhibited discordant reverse remodeling in the left ventricle and the left atrium. CRT-D patients with LBBB and complete left-sided reverse remodeling had a significantly lower risk of HF and death, HF alone, and death alone during long-term follow-up than patients with discordant or lesser reverse remodeling. (MADIT-CRT: Multicenter Automatic Defibrillator Implantation With Cardiac Resynchronization Therapy [MADIT-CRT]; NCT00180271).
Dit artikel is een samenvatting van een publicatie in Journal of the American College of Cardiology. Voor het volledige artikel, alle details en referenties verwijzen wij u naar de oorspronkelijke bron.
Lees het volledige artikelDOI: 10.1016/j.jacc.2016.06.051